Single Station Bench-Top Leak Test System for Testing Oil Filter Adapters
Mass flow leak testing (using M1075y) provides a quick and direct measurement.
Five different filter variations can be tested as the clamp is designed to support interchangeable clamp springs designed for a specific filter adapter.Gage R&R meets automotive requirements of less than 20%.
Test specifications required;
- Test Pressure: 6 bar
- Accept/Reject Limit: 5.0 sccm
- Test Time: 25 seconds approximate
Model Changeover: 5 different filter variations can be tested
InterTech has its sales and demonstration offices in Chennai, India. For sales enquiries, you may contact us at;